Description of the
Access Control Safety Light Curtain with Automatic/Manual Restart and EDM Safety Light Curtain: Type 2, SILCL 1, PL c, Cat. 2 Cross Section: 35 x 45 mm Hardware configuration: no programming necessary, easy to install and replace Connection and configuration through M12 connectors Unshielded cables up to 100 m can be used to connect the Safety Light Curtain What's in the Box: Emitter, Receiver and Standard Fastening Brackets
Specifications
- Product
- Safety Light Curtains
- Response Time (ms)
- 5
- Max. Range (m)
- 18
- Resolution (mm)
- Multi-Strahl
- Number of Beams
- 2
- Monitoring Height (mm)
- 500
- Safety Output Type
- 2 fail-safe PNP (500 mA at 24 VDC) with short-circuit, overload, reverse polarity protection
- Total Height (mm)
- 711
- Connections
- 5-pin M12 Connector (Transmitter), 8-pin M12 Connector (Receiver)
- Safety Level
- Type 2 - PL c
- Scanning
- Access control
- Operating Range (m)
- Selectable: 0 ... 6 m – low range / 1 ... 18 m – high range
- Safety Level (SIL / PL)
- Type 2 - SILCL 1 - PL c - Cat. 2
- Operating System
- Transmitter / Receiver
- Number of Safety Outputs
- 2 PNP (500 mA at 24 VDC)