Item no:REER-1200090
SR X
Prices are only visible to registered customers. Please sign in or request a login.
replacement time approx. 2 week(s)
Item no:REER-1201710
Description of the
Control Unit for Type 2 Safety Photocells Safety interface module for safety photocells Ilion and Ulisse, which can be combined to form a Type 2 safety system. Up to 4 photocells may be connected - Guided-contact safety relays - Start/Restart interlock - EDM Feedback input for external contactors monitoring - Self test every 5 seconds
Specifications
- Product
- Safety Controllers & Interfaces
- Response Time (ms)
- ≤ 20
- Connections
- Removable terminal blocks, contact screws
- Safety Level
- Type 2 - PL c
- Safety Relay Outputs
- 2 NO (6A at 250 VAC)
- Safety Level (SIL / PL)
- Type 2 - SILCL 1 - PL c - Cat. 2